In many cases, stable temperatures and an optimum indoor environment are decisive for performance levels, comfort and operational reliability. Made to measure, high performance refrigeration technology from WOLF provides you with efficient complete solutions with the perfect combination of low investment and operating costs, space saving integration and operational reliability.
High quality and flexibility for all individual application requirements are continuously ensured at the factory by the WOLF Refrigeration Engineering department. Furthermore, you can rely on a competent and strong partner in the planning, implementation and support of your cooling applications.
![[Translate to International:] KG Top Kälte [Translate to International:] KG Top Kälte](/fileadmin/_processed_/a/0/csm_KG_Top_Kaelte_172ee46b45.jpg)
The refrigeration unit is fully installed in an empty, sound-insulated section of the KG Top, in the extract air flow of the central ventilation unit. Retrofitting is easy, even with appliances from other manufacturers. The integral refrigeration units from WOLF offer several important benefits that you should consider during the design stage.
The compressor/compressor set is installed on anti-vibration mounts. Assembled as one compact unit, it incorporates intake and pressure shut-off valves and a crankcase heater with a refrigerant collector, refrigerant dryer, sight glass, high/low pressure switches and an electronic or thermostatic expansion valve.
![[Translate to International:] DR Verdichtersatz [Translate to International:] DR Verdichtersatz](/fileadmin/Wolf_Profi/Sliderbilder_profi/DR-Verdichtersatz.jpg)
If there are several compressors in the refrigeration circuit, the units are also equipped with an oil regulation system, and are pressure-tested, evacuated and filled with shielding gas in their delivered condition. WOLF refrigeration units feature the necessary safety equipment in accordance with UVV/VGB 20 and are assembled and tested in line with the relevant standards and regulations.
A control panel for operating the refrigeration unit, sheet steel casing, a mounted door with rubber seal and the cam lock, RAL 7035 paint finish, contactors, fuses, etc. on the mounting plate with wiring ducts, main switches and indicator lights in the door with flexible wiring, fully assembled and partially wired, tested to VDE 0660 Part 500 and EN 60439-1.
Final installation of the refrigeration pipework, wiring of the refrigeration components to the refrigeration control panel and commissioning of the compressor set on site with pressure testing, commissioning report and user instruction.
The compressor/compressor set is installed on anti-vibration mounts. Assembled as one compact unit, it incorporates intake and pressure shut-off valves and a crankcase heater, a refrigerant collector, refrigerant dryer, sight glass, high/low pressure switches and an electronic or thermostatic expansion valve.
If there are several compressors in the refrigerant circuit, it is also equipped with an oil regulation system. Pressure-tested and evacuated, and filled with shielding gas in its delivered condition. Safety equipment in accordance with UVV/VGB 20. Assembled and tested in line with relevant standards and regulations.
![[Translate to International:] IK Verdichtersatz [Translate to International:] IK Verdichtersatz](/fileadmin/Wolf_Profi/Sliderbilder_profi/IK_Verdichtersatz.jpg)
Control panel for operating the refrigeration unit, sheet steel casing, mounted door with rubber seal and cam lock, RAL 7035 paint finish, contactors, fuses, etc. on the mounting plate with wiring ducts, main switches and indicator lights in the door with flexible wiring, fully assembled and partially wired, tested to VDE 0660 Part 500 and EN 60439-1.
Final installation of the refrigeration pipework, wiring of the refrigeration components to the refrigeration control panel and commissioning of the compressor set on site with pressure testing, commissioning report and user instruction.
The compressor/compressor set is installed on anti-vibration mounts. Assembled as one compact unit, it incorporates intake and pressure shut-off valves and a crankcase heater with a refrigerant collector, refrigerant dryer, sight glass, high/low pressure switches and an electronic or thermostatic expansion valve.
If there are several compressors in the refrigerant circuit, it is also equipped with an oil regulation system. Pressure-tested and evacuated, and filled with shielding gas in its delivered condition. Safety equipment in accordance with UVV/VGB 20. Assembled and tested in line with relevant standards and regulations.
![[Translate to International:] IKS Verdichtersatz [Translate to International:] IKS Verdichtersatz](/fileadmin/Wolf_Profi/Sliderbilder_profi/IKS_Verdichtersatz.jpg)
Control panel for operating the refrigeration unit, sheet steel casing, mounted door with rubber seal and cam lock, RAL 7035 paint finish, contactors, fuses, etc. on the mounting plate with wiring ducts, main switches and indicator lights in the door with flexible wiring, fully assembled and partially wired, tested to VDE 0660 Part 500 and EN 60439-1.
Final installation of the refrigeration pipework, wiring of the refrigeration components to the refrigeration control panel and commissioning of the compressor set on site with pressure testing, commissioning report and user instruction.