EN

Conventional wall mounted gas combi boiler
CGU-2K

ComfortLine conventional wall mounted gas combi boiler
Model / Performance
  • CGU-2-10
  • CGU-2K-18
  • CGU-2K-24
  • KEY FACTS
  • Specification
  • Downloads
  • Conventional wall mounted gas combi boiler for open flue operation
  • Tested to current EC directives
  • Electronic ignition and monitoring
  • Water-cooled, atmospheric premix burner for natural gas E, LL and LPG
  • Wolf low NOx unit with Hydro Tec system designed for the cleanest combustion
  • Control unit with eBus capability for connection to Wolf digital control accessories
  • Modulating controlled output in heating and DHW mode
  • Equipped as standard with variable high efficiency pump, 3-way changeover valve,
  • 10 litre expansion vessel
  • Easy installation and operation
  • Electronic output matching, no adjustment necessary at the gas combination valve
  • High standard seasonal efficiency [to DIN] up to > 94 % (net cv) / 85 % (gross cv) for the best possible energy efficiency
  • Emissions to NOx class 5 White (RAL 9016) powder-coated casing
  • High energy efficiency and compact design
technical drawing
Please choose model
Conventional wall mounted gas combi boiler CGU-2K
TYPE CGU-2-10CGU-2K-18CGU-2K-24
Energy efficiency class, central heating C CC
Energy efficiency class, DHW heating -AA
Output rangekW7.5-104331310.9-24
Input rangekW8.3-11.28.8-20.212.0-26.5
Heating flow outside diameterG¾"¾"¾"
Heating return outside diameterG¾"¾"¾"
DHW connection or cylinder flowG¾"¾"¾"
Cold water connection or cylinder returnG¾"¾"¾"
Gas connectionG¾"¾"¾"
Flue gas connectionmm110110130
Air/flue pipe connectionmm---
Air/flue gas routingTypeB11BSB11BSB11BS
Gas category II2ELL3PII2ELL3PII2ELL3P
Gas supply details
Natural gas E/H (net cv = 9.5 kWh/m³ = 34.0 MJ/m³)m³/h1,32,12,8
Natural gas LL (net cv = 8.1 kWh/m³ = 31.0 MJ/m³)m³/h1,52,33,1
LPG P (net cv = 12.9 kWh/kg = 46.3 MJ/kg)kg/h0,81,52,1
Gas supply pressure, natural gasmbar202020
Gas supply pressure, LPG Pmbar505050
Standard seasonal efficiency [to DIN] at 75/60 °C (net cv/gross cv)% 93 / 8594 / 85
Residual head for heating circuit: high efficiency pump (EEI < 0.23)
430 l/h pump rate (10 kW at Δt = 20 K)mbar250250-
770 l/h pump rate (18 kW at Δt = 20 K)mbar-250250
1030 l/h pump rate (24 kW at Δt = 20 K)mbar--250
DHW flow ratel/min-2.7-5.82.7-7.7
Max. operating pressurebar 33
Max. DHW temperature 1)°C-5555
Expansion vessel, nominal capacityl101010
Expansion vessel, pre-charge pressurebar0,750,750,75
Required draught for the heat generatorPa1,51,51,5
Flue gas temperature 2)°C84 / 10180 / 12380 / 125
Flue gas mass flow rate 2)g/s12.8 - 13.112.8 / 13.915.0 / 19.0
NOx class 555
Power consumption (standby / max.)W304683046830468
IP ratingIPIP X4DIP X4DIP X4D
Total weightkg393941
Electrical connection 230 V / 50 Hz
Conventional wall mounted gas combi boiler CGU-2K
ErP product datasheet
CGU-2K-24 ErP label
CGU-2K-18 ErP label
CGU-2-10 ErP product datasheet
CGU-2-10 ErP label