Model / Performance
  • SWP-200
  • SWP-260
  • SWP-260B
  • Key Facts
  • Specification
  • Downloads
  • DHW heat pump, fully wired
  • Recirculation air, extract air and outdoor air operation possible via duct system
  • For cooling and dehumidification of basements and storerooms
  • Secure separation of refrigerant from drinking water thanks to external safety condenser
  • Increase in on-site consumption of photovoltaic power thanks to Smart Grid Ready connection at inverter (increased set value up to 75 °C)
  • Integral electric heater rod, 1.5 kW
  • For SWP-260 with additional internal indirect coil heat exchanger, 1 m², for dual mode operation (solar/gas/oil/biomass)
  • Integral control unit with 2 time programs, pasteurisation function and demand-dependent defrost function
  • SWP-260 and SWP-260B with 2 additional lateral air duct connections for rooms with low ceilings
  • Air connector, 160 mm, for air routing with Wolf ISO pipe DN160
Please choose model
DHW Heat pump SWP
Type SWP 200 260

General data

Energy efficiency class, DHW heating A A
Type of heat pump DHW DHW
Conformity CE CE
IP rating, indoor unit IP X4 IP X4

Dimensions

Diameter x height mm Ø650 x 1714 Ø650 x 2000
Lower magnesium anode (length 250 mm) A mm - 310
Electric heating element B mm 650 920
Upper magnesium anode (length 400 mm) C mm 960 1250
Total height D mm 1714 2000
Heat pump diameter E mm 650 650
Cylinder diameter F mm 604 604
Cold water connection G mm 70 70
Heat exchanger return H mm - 275
Condensate drain I mm 526 818
Heat exchanger flow J mm - 820
DHW circulation K mm 795 1085
DHW connection L mm 1104 1391
Height when tilted mm 1780 2080

Refrigerant circuit

Refrigerant type / charge weight -/kg - / kg R134a / 0,9 R134a / 0,9
Compressor type Rotating piston Rotating piston
Maximum operating pressure bar 24 24
Heat pump heating output kW 1.9 1.9
Electric heating element heating output kW 1.5 1.5
Total heating output kW 3.4 3.4
Draw-off profile to EN 16147 L XL
COP (A15 / W10-55, EN16147) - 3.24 3.54
COP (A7 / W10-55, EN16147) - 2.94 3.08
Sound power level (with reference to EN ISO 3741-2010) 59 59
Operating limit temperatures, DHW (heat pump only) +5 bis +56 +5 bis +56
Maximum DHW temperature (heat pump + electric heating element) 70 70
Min./max. operating limit temperatures for air -0.18421052631578946 -0.18421052631578946
Min./max. operating limit temperatures for installation room 0.13157894736842105 0.13157894736842105
Air flow rate m3/h 350 - 500 350 - 500
Max. available head Pa 200 200
Supply/extract air vent diameters mm 160 at the top 160 (at the top and side)
Cold water connection G 1“
Heat exchanger return G - 1 1/4 * DHW circulation G 3/4" Heat exchanger flow G - 1 1/4 *
DHW connection G 1“
Condensate drain G 1/2“
Cylinder capacity l 200 260
ECO heat-up time (10-55 °C) h:m 7:39 10:14
Boost heat-up time (10-55 °C) h:m 3:58 5:06
NL50 output factor NL50 1.6 2.7
Max. delivery capacity at 40 °C without reheating at a cylinder temperature of 55 °C l 276 342
Internal indirect coil surface area m2 1,0
Internal indirect coil capacity l 6,8
Internal indirect coil bar/°C 10 / 110
Max. operating pressure, cylinder bar 10
Corrosion protection Enamelled cylinder, 1x magnesium anode Enamelled cylinder, 2x magnesium anode

Weight

Weight kg 95 115

Electrics

Power supply/fuse protection, heat pump including electric heating element 1~NPE, 230VAC, 50Hz / 16A (C), steckerfertig 1~NPE, 230VAC, 50Hz / 16A (C), steckerfertig
Power consumption, electric heating element kW 1.5 1.5
Maximum power consumption, heat pump kW 0.53 0.53