EN

Gas condensing solar centre
CSZ-2

ComfortLine gas condensing solar centre with solar cylinder, solar pump assembly and control unit
Model / Performance
  • CSZ-2 14/300R
  • CSZ-2 20/300R
  • CSZ-2 24/300R
  • KEY FACTS
  • Specification
  • Downloads
  • Wall mounted gas condensing boiler, sealed combustion chamber, for open flue or room sealed operation
  • High standard seasonal efficiency [to DIN] up to 110 % (net cv) / 99 % (gross cv) for the best possible energy efficiency
  • Meets the requirements for the "Blue Angel" certificate of environmental excellence to RAL‑UZ 61 when operated with natural gas; premix burner for natural gas E, LL and LPG; variable modulating heating output from 1.8 kW
  • With expansion vessel, modulating high efficiency pump (EEI < 0.23) and 3-way valve as standard
  • Heating water heat exchanger can be pivoted under system pressure for maintenance without having to drain the heating water
  • Wolf "ALUPro" coated heating water heat exchanger
  • Convenient access to all components for quick installation and easy operation and maintenance
  • Easy flue gas emissions testing from outside without opening the appliance
  • Efficient combustion technology with gas-adaptive, self-calibrating combustion controller that adjusts automatically to the gas quality – flue gas inspection only required every 3 years
  • Conversion between natural gas and LPG operation without a conversion kit
  • Automatic CO2 settings with self-calibrating combustion controller for all gas types (natural gas, LPG)
  • New Wolf WRS control system can be set and adjusted via smartphone or PC
  • Optimum utilisation of condensing technology by controlling the spread without an overflow valve; no return temperature raising required; ISM7i LAN/WLAN module allows communication via smartphone, laptop or PC
technical drawing
Please choose model
Gas condensing solar centre CSZ-2
TYPECSZ-2-14/300RCSZ-2-20/300RCSZ-2-24/300R
Energy efficiency class, central heating AAA
Energy efficiency class, DHW heating AAA
Rated heating output at 80/60 °CkW13,518.9/22.2 1)23.8/27.1 1)
Rated heating output at 50/30 °CkW15,220,425,8
Rated heat inputkW1419.6/23.0 1)24.6/28.0 1)
Lowest heating output (modulating) at 80/60 °CkW1.8/4.6 2)3.8/6.8 2)4.8/6.8 2)
Lowest heating output (modulating) at 50/30 °CkW2.1/5.4 2)4.4/7.4 2)5.6/7.4 2)
Lowest heat input (modulating)kW1.9/4.9 2)3.9/6.9 2)4.9/6.9 2)
Heating flow connectionG¾" (DN 20)¾" (DN 20)¾" (DN 20)
Heating return connectionG¾" (DN 20)¾" (DN 20)¾" (DN 20)
DHW connectionG¾"¾"¾"
Cold water connection/DHW circulationG¾"¾"¾"
Gas connectionR½"½"½"
Air/flue pipe connectionmm60/10060/10060/100
Air/flue gas routingTypeB23P, B33P, C13(x), C33(x), C43(x), C53(x), C63(x), C83(x), C93(x)  
Gas categorym³/hII2N3B/PII2N3BII2N3B
"Gas supply details
Natural gas E/H (net cv = 9.5 kWh/m³ = 34.2 MJ/m³)"m³/h1,442.06/2.422.52/2.95
Natural gas LL (net cv = 8.6 kWh/m³ = 31.0 MJ/m³)m³/h1,592.28/2.672.79/3.25
LPG P (net cv = 12.8 kWh/m³ = 46.1 MJ/m³)kg/h1,071.53/1.801.87/2.19
Natural gas supply pressure (permissible min./max.)mbar20 (17-25)20 (17-25)20 (17-25)
LPG gas supply pressure (permissible min./max.)mbar50 (42.5-57.5)50 (42.5-57.5)50 (42.5-57.5)
Standard seasonal efficiency [to DIN] at 40/30 °C (net cv/gross cv)%110/99110/99110/99
Standard seasonal efficiency [to DIN] at 75/60 °C (net cv/gross cv)%107/96107/96107/96
Efficiency at rated load at 80/60 °C (net cv/gross cv)%98/8898/8898/88
Efficiency at 30 % partial load and TR = 30 °C (net cv/gross cv)%109/98109/98109/98
Flow temperature, factory setting°C757575
Flow temperature up to approx.°C909090
Max. overall pressure, heating circuitbar333
"Residual head for heating circuit: high efficiency pump (EEI < 0.23)
600 l/h pump rate (14 kW at Δt = 20 K)"mbar550550550
860 l/h pump rate (20 kW at Δt = 20 K)mbar-430430
1030 l/h pump rate (24 kW at Δt = 20 K)mbar--280
Max. permissible overall pressure, DHWbar101010
DHW temperature range (adjustable)°C15-6515-6515-65
Water capacity of the heat exchanger, heating/solarl7.4 / 10.27.4 / 10.27.4 / 10.2
Nominal cylinder capacityl285285285
Spec. water throughput "D" at ΔT = 30 Kl/min20,524,524,5
Continuous DHW outputl/h (kW)366 (14.6)560 (23.1)684 (27.8)
Performance factor to DIN 4708NL1,52,32,3
DHW outputl/10 min175210210
Standby heat loss to EN 12897kWh/24 h2,32,32,3
Cylinder corrosion protection Two-layer enamel coating to DIN 4753  
Expansion vessel, total capacityl101010
Expansion vessel, pre-charge pressurebar0.75-0.950.75-0.950.75-0.95
Flue gas temperature 80/60-50/30 at Qmax°C62-4570-5076-50
Flue gas temperature 80/60-50/30 at Qmin°C30-2530-2533-27
Flue gas mass flow rate at Qmaxg/s6,28.8/10.7 1)10.9/13.0 1)
Flue gas mass flow rate at Qming/s0,91,82,3
Available gas fan draught at QmaxPa125135180
Available gas fan draught at QminPa101417
Flue gas category G52G52G52
NOx class 555
Amount of condensate at 50/30 °Cl/happrox. 1.4approx. 2.0approx. 2.4
Condensate pH value approx. 4.0approx. 4.0approx. 4.0
Power consumption on standbyW333
Maximum power consumptionW17-45/59 1)17-51/63 1)17-62/88 1)
IP ratingIPIP X4DIP X4DIP X4D
Electrical connection/fuse protection  230 V / 50 Hz / 16 A/B160 (35+125)
Total weightkg160 (35+125)160 (35+125)160 (35+125)
Installation weight (filled with water)kg583583583
Gas condensing solar centre CSZ-2