Kontakt
DE
WOLF
International
Languages
German
English
Countries
Germany
International
Netherlands
France
Spain
Poland
Russia
Italy
China
Slovakia
Czech Republic
Worldwide
Partner
Europe
Asia
Africa
Oceania
Americas
Choose Country
Austria
Belgium
Bulgaria
Croatia
Czech Republic
Denmark
Estonia
Finland
France
Germany
Greece
Hungary
Iceland
Ireland
Italy
Latvia
Lithuania
Luxembourg
Macedonia
Moldova
Netherlands
Norway
Poland
Portugal
Romania
Russia
Serbia
Slovakia
Slovenia
Spain
Sweden
Switzerland
Ukraine
United Kingdom
Austria
Belgium
Bulgaria
Croatia
Czech Republic
Denmark
Estonia
Finland
France
Germany
Greece
Hungary
Iceland
Ireland
Italy
Latvia
Lithuania
Luxembourg
Macedonia
Moldova
Netherlands
Norway
Poland
Portugal
Romania
Russia
Serbia
Slovakia
Slovenia
Spain
Sweden
Switzerland
Ukraine
United Kingdom
Armenia
Azerbaijan
China
Georgia
Iran
Israel
Jordan
Kazakhstan
Lebanon
Oman
Qatar
Syria
Turkey
United Arab Emirates
Uzbekistan
Armenia
Azerbaijan
China
Georgia
Iran
Israel
Jordan
Kazakhstan
Lebanon
Oman
Qatar
Syria
Turkey
United Arab Emirates
Uzbekistan
Egypt
Morocco
Tunisia
Egypt
Morocco
Tunisia
New Zealand
New Zealand
Chile
Mexico
Chile
Mexico
Replaced with Ajax Call
Home
Privatkunden
Übersicht
Beratung
Produkte
Installateur Suche
Service
Downloads
5 Jahre Garantie
Aktionen
Über WOLF
Übersicht
Über uns
Aktuelles
Presse
Lieferanten
Referenzen
Karriere
)
Klima-Profi
Übersicht
Produkte & Systeme
Anwendungsbereiche
Technologie
Service & Tools
Luftreiniger
Downloads
SHK-Profi
Übersicht
Produkte
Service
Tools
Downloads
Akademie
Gipfelstürmer
Power Systems
DE
myWOLF
Login
Dashboard
Suche
DE
SHK-Profi
Produkte
Gas-Brennwertkessel
Gas condensing boiler MGK-2_130-300
Gas condensing boiler
MGK-2_130-300
Floorstanding gas condensing boiler for condensing operation and DHW heating for natural gas E, LL
Modell / Leistung
MGK-2-130
MGK-2-170
MGK-2-210
MGK-2-250
MGK-2-300
Key Facts
Technische Daten
Downloads
Modulation range 17 - 100 %
Standard seasonal efficiency [to DIN] net cv up to 110 %
No minimum volume of circulation water
Option to integrate neutralising system set with booster and condensate removal pump
Extremely quiet operation
Fully encased and thermally insulated
Compact design, fits through an 800 mm door
Integral back draught safety device for flue cascade operation
ISM7i LAN/WLAN module allows communication via smartphone, laptop or PC
0-10 V input for BMS system
230 V fault message output
Common sensor connection option for low loss header
Possibility of cascade operation with up to 5 appliances
Modell wählen
Gas condensing boiler
MGK-2_130-300
Type
MGK-2
130
170
210
250
300
General data
Rated heating output at 80/60 °C
kW
118
157
196
233
275
Rated heating output at 50/30 °C
kW
126
167
208
250
294
Rated heat input
kW
120
160
200
240
280
Lowest heating output (modulating) at 80/60 °C
kW
23
27
34
39
45
Lowest heating output (modulating) at 50/30 °C
kW
24
30
37
44
49
Lowest heat input (modulating)
kW
23
28
35
41
46
Heat input modulation range
%
19-100
17-100
17-100
17-100
17-100
Amount of condensate at 40/30 °C
l/h
12
16
20
24
28
Condensate pH value
ca. 4,0
ca. 4,0
ca. 4,0
ca. 4,0
ca. 4,0
Gas connection
R
1“
1½“
1½“
1½“
1½“
Air/flue gas routing
Type
B23(P), B33, C33(x), C43(x), C53(x), C63(x), C83, C93(x)
Efficiency
η 80/60 at Qmax
%
98.1
98
98.1
98
98
η 50/30 at Qmax
%
104.1
104.2
104.3
103.9
105.2
η TR30 at 30%
%
107.8
106.9
106.7
106.6
106.8
Dimensions
Height
A mm
1300
1300
1300
1300
1300
Width
B mm
995
1355
1355
1355
1355
Depth
C mm
640
640
640
640
640
Flue diameter
mm
160
160
160
160
200
Combustion air supply 4)
mm
160
160
160
160
160
Heating flow outside diameter
R
1½“
2“
2“
2“
2“
Heating return outside diameter
R
1½
2“
2“
2“
2“
Gas category
Germany
II2ELL3P
II2ELL3P
II2ELL3P
II2ELL3P
II2ELL3P
Austria
II2H3P
II2H3P
II2H3P
II2H3P
II2H3P
Switzerland
I2H
I2H
I2H
I2H
I2H
Gas supply details:
Natural gas E/H (net cv = 9.5 kWh/m³ = 34.2 MJ/m³)
m³/h
13.1
16.8
21
25.2
29.4
Natural gas LL (net cv = 8.6 kWh/m³ = 31.0 MJ/m³) 1)
m³/h
14.6
18.6
23.3
27.9
32.6
LPG P (net cv = 12.8 kWh/kg = 46.1 MJ/kg) 2)
kg/h
9.6
12.5
15.6
18.7
21.8
Gas supply pressure:
Natural gas E/LL
mbar
20
20
20
20
20
LPG P
mbar
50
50
50
50
50
Water capacity of the heating water heat exchanger
l
12
15.4
16
20
22
Max. permissible boiler pressure
bar
6
6
6
6
6
Max. permissible flow temperature
°C
90
90
90
90
90
Available gas fan draught
Pa
10-200
10-150
10-150
10-150
10-150
Flue gas temperature 80/60-50/30 at Qmax
°C
65-45
65-45
65-45
65-45
65-45
Flue gas temperature 80/60-50/30 at Qmin
°C
55-35
55-35
55-35
55-35
55-35
Max. flue gas mass flow rate
g/s
56.7
72.5
90.8
108.9
127.1
Flue gas category to DVGW G 635
G52
G52
G52
G52
G52
Heating water pressure drop with 20 K spread
mbar
95
100
115
135
160
Electrical connection
V~/Hz
1~ NPE / 230VAC / 50Hz
Integral fuse (medium time lag)
A
4
4
4
4
4
Standby power consumption
W
5
5
5
5
5
Power consumption at partial load/full load
W
30 / 240
42 / 258
42 / 291
43 / 326
48 / 350
IP rating
IP20
IP20
IP20
IP20
IP20
Sound pressure level at full load 3)
dB(A)
~ 49
~ 54
~ 54
~ 54
~ 54
Weight
Total weight (empty)
kg
195
250
271
292
313
Gas condensing boiler
MGK-2_130-300
Technical broschure
4800745_201804_WOLF_Gas_Condensing_Boilers_MGK-2-130__170__210__250__300.pdf
(PDF 2 MB)