EN

DHW cylinder
CSW

ComfortLine DHW cylinder made from steel with enamel coating
Model / Performance
  • CSW 120
  • Key Facts
  • Specification
  • Downloads
  • Accessory for WOLF CGU-2K wall mounted gas boiler, for example
  • R ¾" connections for flow, return, cold water, hot water and DHW circulation for easy connection and also a cleaning aperture, all at the top of the cylinder
  • White RAL 9016 powder-coated casing
  • Rigid PUR foam thermal insulation all around the cylinder, applied directly to the cylinder surface, highly effective and with low heat losses
  • Corrosion protection through enamelled cylinder interior and internal indirect coil to DIN 4753, part 3. Additional corrosion protection through sacrificial magnesium anode integrated into the inspection and cleaning apertures
  • Internal indirect coil with large heat exchanger surface area for short heat-up times
  • High continuous DHW output
  • R ½" drain at the front, incl. drain valve and hose connection
  • Adjustable feet
  • 5 year statutory warranty
Please choose model
DHW cylinder CSW
Type CSW 120

General data

Energy efficiency class B
Cylinder capacity l 115
Continuous cylinder output (80/60 – 10/45 °C) kW – l/h 29 – 710
Standby heat loss kWh/24h 1.1100000000000001
Performance factor NL 1
Permissible operating pressure, DHW bar 10
Permissible operating pressure, heating water bar 12
Max. permissible cylinder water temperature °C 95
Max. permissible heating water temperature °C 110
Cold water connection R ¾“
DHW connection R ¾“
Cylinder flow R ¾“
Cylinder return R ¾“
DHW circulation R ¾“
Drain R ½“
Sensor well Ø mm 12
Dry weight kg 65
DHW cylinder CSW
CSW ErP product data sheet