Specifications

Model type
CGU-2-10
CGU-2K-18
CGU-2K-24
Energy efficiency class
Central heating energy efficiency class
A+++ → D
C
C
C
Energy efficiency class, DHW heating
A+ → F
-
A
A
Output range
kW
7.5-10
8-18
10.9-24
Input range
kW
8.3-11.2
8.8-20.2
12.0-26.5
Heating flow line outside diameter
Thread
¾“
¾“
¾“
Heating return line outside diameter
Thread
¾“
¾“
¾“
DHW connection or cylinder flow
Thread
¾“
¾“
¾“
Cold water connection or cylinder return
Thread
¾“
¾“
¾“
Outdoor gas connection
Thread
1/2“
1/2“
1/2“
Dimensions
Flue connection
mm
110
110
130
Balanced flue connection
mm
-
-
-
Balanced flue
Type
B11BS
B11BS
B11BS
Gas category
II2ELL3P
II2ELL3P
II2ELL3P
Gas supply details for natural gas E/H (net cv = 9.5 kWh/m³ = 34.0 MJ/m³)
m³/h
1.3
2.1
2.8
Natural gas LL (net cv = 8.1 kWh/m³ = 31.0 MJ/m³)
m³/h
1.5
2.3
3.1
LPG P (net cv = 12.9 kWh/kg = 46.3 MJ/kg)
kg/h
0.8
1.5
2.1
Gas supply pressure, natural gas
mbar
20
20
20
Gas supply pressure, LPG P
mbar
50
50
50
Standard seasonal efficiency [to DIN] at 75/60°C (net cv/gross cv)
%
93 / 85
94 / 85
Residual head for heating circuit: High-efficiency pump (EEI < 0.23) 430 l/h pump rate (10 kW at Δt = 20 K)
mbar
250
250
-
770 l/h pump rate (18 kW at Δt = 20K)
mbar
-
250
250
1030 l/h pump rate (24 kW at Δt = 20 K)
mbar
-
-
250
DHW flow rate
l/min
-
2.7-6
2.7-8
Max. operating pressure
bar
3
3
Max. DHW temperature 1)
°C
- / 15 - 65
40 - 65 / 15 - 65
40 - 65 / 15 - 65
Expansion vessel, nominal capacity
litres
10
10
10
Expansion vessel, pre-charge pressure
bar
0.75
0.75
0.75
Required draught for the heat generator
Pa
1.5
1.5
1.5
Flue gas temperature 2)
°C
84 / 101
80 / 123
80 / 125
Flue gas mass flow rate 2)
g/s
12.8 - 13.1
12.8 / 13.9
15.0 / 19.0
NOx class
6
6
6
Power consumption (standby / max.)
W
58 / 5
58 / 5
58 / 5
IP rating
IP
IP X4D
IP X4D
IP X4D
Total weight
kg
38
38
40
Electrical connection
230V / 50Hz

Specifications

  • CGU-2-10

  • CGU-2K-18

  • CGU-2K-24

    Energy efficiency class
    Central heating energy efficiency class (A+++ → D)
    C
    C
    C
    Energy efficiency class, DHW heating (A+ → F)
    -
    A
    A
    Output range (kW)
    7.5-10
    8-18
    10.9-24
    Input range (kW)
    8.3-11.2
    8.8-20.2
    12.0-26.5
    Heating flow line outside diameter (Thread)
    ¾“
    ¾“
    ¾“
    Heating return line outside diameter (Thread)
    ¾“
    ¾“
    ¾“
    DHW connection or cylinder flow (Thread)
    ¾“
    ¾“
    ¾“
    Cold water connection or cylinder return (Thread)
    ¾“
    ¾“
    ¾“
    Outdoor gas connection (Thread)
    1/2“
    1/2“
    1/2“
    Dimensions
    Flue connection (mm)
    110
    110
    130
    Balanced flue connection (mm)
    -
    -
    -
    Balanced flue (Type)
    B11BS
    B11BS
    B11BS
    Gas category
    II2ELL3P
    II2ELL3P
    II2ELL3P
    Gas supply details for natural gas E/H (net cv = 9.5 kWh/m³ = 34.0 MJ/m³) (m³/h)
    1.3
    2.1
    2.8
    Natural gas LL (net cv = 8.1 kWh/m³ = 31.0 MJ/m³) (m³/h)
    1.5
    2.3
    3.1
    LPG P (net cv = 12.9 kWh/kg = 46.3 MJ/kg) (kg/h)
    0.8
    1.5
    2.1
    Gas supply pressure, natural gas (mbar)
    20
    20
    20
    Gas supply pressure, LPG P (mbar)
    50
    50
    50
    Standard seasonal efficiency [to DIN] at 75/60°C (net cv/gross cv) (%)
    93 / 85
    94 / 85
    Residual head for heating circuit: High-efficiency pump (EEI < 0.23) 430 l/h pump rate (10 kW at Δt = 20 K) (mbar)
    250
    250
    -
    770 l/h pump rate (18 kW at Δt = 20K) (mbar)
    -
    250
    250
    1030 l/h pump rate (24 kW at Δt = 20 K) (mbar)
    -
    -
    250
    DHW flow rate (l/min)
    -
    2.7-6
    2.7-8
    Max. operating pressure (bar)
    3
    3
    Max. DHW temperature 1) (°C)
    - / 15 - 65
    40 - 65 / 15 - 65
    40 - 65 / 15 - 65
    Expansion vessel, nominal capacity (litres)
    10
    10
    10
    Expansion vessel, pre-charge pressure (bar)
    0.75
    0.75
    0.75
    Required draught for the heat generator (Pa)
    1.5
    1.5
    1.5
    Flue gas temperature 2) (°C)
    84 / 101
    80 / 123
    80 / 125
    Flue gas mass flow rate 2) (g/s)
    12.8 - 13.1
    12.8 / 13.9
    15.0 / 19.0
    NOx class
    6
    6
    6
    Power consumption (standby / max.) (W)
    58 / 5
    58 / 5
    58 / 5
    IP rating (IP)
    IP X4D
    IP X4D
    IP X4D
    Total weight (kg)
    38
    38
    40
    Electrical connection