What do you want to know?

Overview of benefits

The CRK collectors meet the requirements set for the Blue Angel certificate of environmental excellence according to RAL UZ 73

Efficient solar thermal collector design for space-conscious installations; Designed for solar thermal operation throughout different seasonal conditions; especially suitable for a combination of DHW heating and central heating backup

Certified by Solar Keymark

Durable: Direct-flow vacuum tube collector based on the thermos flask principle, designed to support thermal insulation within the collector system

Constant: The absorber coating is located within the vacuum tube and is designed to reduce exposure to environmental influences

Flexible: Modular layouts for different roof configurations

Statutory warranty: 5 years

Specifications

CRK-12
Model type
CRK-12
General data
Connections (MS locking ring fitting)
mm
15
Installation angle
15° to 75°
Heat transfer medium
ANRO LS (undiluted)
Solar Keymark registration no.
011-7S321 R
Absorption (energy absorption)
%
> 93.5
Emissions
%
≤ 6
Optical efficiency *
%
64.2
Heat loss coefficient a1 *
W/(m2 K)
0.885
Heat loss coefficient a2 *
W/(m2 K2)
1E-3
Max. stagnation temperature
°C
272
Angle of incidence correction factor K * Iongitudinal / transversal
%
89 / 99
Effective thermal capacity
Coeff in kJ/ (m2 K)
8.416
Max. operating pressure
bar
10
Pressure drop (at 15 l/h x m² and 40°C)
mbar
5
Number of vacuum tubes per collector
Units
12
Glass tube diameter
mm
47 / 33 / 1.6
Gross surface area
m²
2.29
Aperture area
m²
2
Capacity
litres
1.74
Dimensions
Length
mm
1640
Width
mm
1390
Depth
mm
100
Weights
Weight (empty)
kg
32.7

Specifications

CRK-12
  • CRK-12

    General data
    Connections (MS locking ring fitting) (mm)
    15
    Installation angle
    15° to 75°
    Heat transfer medium
    ANRO LS (undiluted)
    Solar Keymark registration no.
    011-7S321 R
    Absorption (energy absorption) (%)
    > 93.5
    Emissions (%)
    ≤ 6
    Optical efficiency * (%)
    64.2
    Heat loss coefficient a1 * (W/(m2 K))
    0.885
    Heat loss coefficient a2 * (W/(m2 K2))
    1E-3
    Max. stagnation temperature (°C)
    272
    Angle of incidence correction factor K * Iongitudinal / transversal (%)
    89 / 99
    Effective thermal capacity (Coeff in kJ/ (m2 K))
    8.416
    Max. operating pressure (bar)
    10
    Pressure drop (at 15 l/h x m² and 40°C) (mbar)
    5
    Number of vacuum tubes per collector (Units)
    12
    Glass tube diameter (mm)
    47 / 33 / 1.6
    Gross surface area (m²)
    2.29
    Aperture area (m²)
    2
    Capacity (litres)
    1.74
    Dimensions
    Length (mm)
    1640
    Width (mm)
    1390
    Depth (mm)
    100
    Weights
    Weight (empty) (kg)
    32.7